Product Description

Monthly increases in outlet temperature and rising pressure drop in plate-fin heat exchangers are common feedback issues in compressor aftercoolers and hydraulic station oil cooling circuits. Per operational monitoring requirements, inlet and outlet temperatures, pressures, and flow rates should be recorded each shift and trend files established. During on-site commissioning, temperature readings after stable operation should be recorded channel by channel, and deviations from design values calculated, helping procurement and maintenance personnel determine whether the cause is insufficient sizing margin, channel fouling, or uneven medium distribution.

Common Issues and Corresponding Actions

Rising outlet temperature is often related to fin channel fouling and oil-side flow deviating from design values; cleaning and flow verification can be scheduled in conjunction with pressure drop changes. When pressure drop increases significantly, check whether channels are blocked and whether connection pipe diameters match. If the temperature difference is too small, verify whether the heat transfer area is consistent with design conditions. The HX-63 features a removable inspection interface in its structure, facilitating on-site inspection of core channels.

Main Technical Parameters

Applicable media are hydraulic oil, compressed air, and water-glycol solution; design pressure and design temperature are determined per the order agreement; core material options include aluminum alloy or stainless steel; connection types support flange and threaded connections. Specific parameters are subject to the accompanying technical documents.

Application Scenarios

Suitable for compressor aftercooling, hydraulic station oil cooling circuits, and construction machinery cooling systems. Procurement personnel should provide medium type, flow rate, inlet and outlet temperatures, and allowable pressure drop during the selection stage to verify heat transfer area and channel arrangement.

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us