Product Description

Three Basic Parameters to Clarify Before Selection

Design and selection personnel should first confirm the air volume to be handled by the heat exchanger and the required heat transfer rate. The GCH-63 finned tube heat exchanger is suitable for working conditions with an air volume range of 2000–8000 m³/h. The base tubes of the heat exchange tubes are Φ16 mm seamless steel tubes, and the fins are aluminum corrugated fins. The fin spacing can be selected between 2.5 and 3.5 mm according to the dust content of the medium. Heat transfer calculation must take into account the inlet and outlet temperature requirements of the hot side and cold side; a margin of 10%–15% is recommended.

Matching Conditions for Materials and Anti-corrosion Solutions

Ambient temperature and relative humidity directly affect material selection. When the ambient temperature is -20 to +60°C and the relative humidity is below 80%, carbon steel base tubes with aluminum fins and anti-rust surface treatment can be used. If used in scenarios such as waste heat recovery from drying lines where slightly corrosive gases are present, stainless steel tubes or additional fin surface coatings are recommended for the base tubes. For working conditions where the relative humidity remains above 80% for long periods or condensate water is present, a material combination with a higher corrosion resistance grade should be selected, and drainage structure design should be considered.

Key Points for Operation Adjustment and On-site Inspection

After the equipment is in place, turn the temperature knob to the required value and observe whether the signal lamp displays normally to determine whether the control circuit is connected. During the commissioning stage, the temperature difference between inlet and outlet air should be measured. Taking a waste heat recovery project on a drying line as an example, the inlet-outlet air temperature difference is required to be no less than 25°C. If the temperature difference is lower than the design value, check whether the fins have accumulated dust, whether the air volume deviates from the rated value, or whether the bypass valve has internal leakage.

Confirmation of Installation Space and Pipe Connection Direction

During selection, the length, width, and height dimensions of the on-site installation space must be verified. The GCH-63 offers both horizontal and vertical airflow directions, and the pipe connection orientation can be specified at the time of ordering according to the piping layout. A maintenance space of no less than 400 mm is recommended on the fin side for subsequent cleaning and maintenance.

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us