Desktop|中文
Home About Us
Products +
Company News Industry Trends Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

BHX-80 Plate-Fin Heat Exchanger: FAQ on Operation and Maintenance

Published: 2026-10-25

产品价格:0.00

Views: 2922

Category: 板翅式换热器

Product Description

On-Site Verification of Medium and Material Compatibility

The media that plate-fin heat exchangers can handle include hydraulic oil, compressed air, and water-glycol solution. Before overhauling or replacing the core, on-site O&M personnel should first verify the correspondence between the medium type and the materials of the fins, partition plates, and seals. Under hydraulic oil conditions, attention should be paid to the compatibility between seals and the aluminum core; when compressed air contains water, it should be confirmed whether there is a risk of channel blockage caused by water condensation in the low-temperature section; for water-glycol solution, the concentration and pH should be tested regularly to avoid corrosion of the inner channel walls after long-term operation. When the medium composition changes, it is recommended to simultaneously re-verify material compatibility, and it is not advisable to directly put the unit into service using the original parameters.

Verification of Flow Distribution During Low-Load Stages

After the equipment enters the low-load operation stage, the flow distribution of each fluid stream tends to deviate from the design condition, manifesting as outlet temperatures of some channels being too high or too low. Under stable operating conditions, O&M personnel can record the outlet temperature of each condition and compare them item by item with the design values to determine whether the flow distribution is uniform. If a deviation is found, adjustments can be made in combination with the on-site valve opening and the operating status of the pump set, and the temperature data before and after adjustment should be retained to provide a basis for subsequent optimization of operating parameters. This step does not require disassembling the core and is work that can be completed during routine inspections.

Key Maintenance Points When Installation Space Is Limited

The BHX-80 model is suitable for applications requiring simultaneous heat exchange of multiple fluid streams, such as air separation pre-cooling, hydraulic oil cooling, and compressor interstage cooling. It has a large heat exchange area per unit volume, and its installation location is often relatively compact. During maintenance, the inspection access and lifting space should be confirmed in advance to avoid fin damage caused by insufficient disassembly space. The fin channels are relatively narrow, so high-pressure water guns should not be used for direct flushing during cleaning. It is recommended to select the appropriate cleaning method according to the medium type and to check the sealing status of each interface after reassembly.

Retention of Operating Records

Daily records of outlet temperature, flow rate, and pressure drop are the basic data for judging the trends of channel scaling and blockage. It is recommended to record key parameters by shift. When pressure drop rises or heat exchange performance declines, historical data can be traced back to determine the time period when the problem occurred, and then targeted inspection or cleaning can be arranged.

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us