HRY Series Sheathed Electric Heater Detailed Information



Product Features: The HRY series sheathed electric heater adopts the form of multiple U-shaped electric heating elements matched with multiple special-shaped sheaths, featuring large heat dissipation area, fast heat transfer, long service life, and convenient replacement and maintenance.



HRY Series Sheathed Electric Heater Detailed Information:


Used for heating hydraulic and lubricating oil in hydraulic lubrication devices, and also for heating non-corrosive gases or liquids.  


Product Features:


1. Adopts multiple U-shaped electric heating elements matched with multiple special-shaped sheaths, featuring large heat dissipation area, fast heat transfer, long service life, and convenient replacement and maintenance.      


2. Due to the use of multiple U-shaped electric heating elements matched with multiple special-shaped sheaths, if a certain electric heating element is damaged, only that damaged element needs to be replaced without replacing the entire heating source, greatly reducing the user's subsequent investment.


3. The surface load design can be determined according to customer requirements; the standard surface load design is 0.7 W/cm².


4. The sheathed tubular electric heater can be optionally equipped with liquid expansion thermostat, manual reset, AC contactor and other electrical equipment. If the heater needs temperature adjustment function, only a temperature control device needs to be installed. When ordering, add the letter "T" after the model number; if automatic constant temperature function is required, the heater must be equipped with a thermostat and contactor, and add the letters "TH" after the model number when ordering.


5. Working voltage allowable error: not greater than 1.1 times its rated value. The shell should be effectively grounded.


6. Working environment: relative humidity not greater than 95%, no explosive, flammable, or corrosive gases.


7. Heater material: carbon steel or stainless steel.


8. Maximum working temperature: 200°C.


9. Working pressure: less than 0.6 MPa.


10. Specifications and dimensions: see the table and attached figure on the next page.


Usage, Maintenance, and Precautions:             


1. Dimension "B" in the outline drawing must be fully immersed in the oil to avoid burning the components.


2. The heated medium should be non-corrosive.


3. When melting solid oils such as asphalt and paraffin, use reduced voltage first, then increase to rated voltage after melting, to prevent excessive heat concentration and reduce component service life.          


4. If carbon deposits are found on the surface of the heating tube, they must be completely removed before use to avoid reduced efficiency or even burning of components.   


5. Components should be stored in a dry place. If the insulation resistance drops below 1 megohm after long-term storage, the heating core can be removed and dried in an oven at about 200°C for several hours (or the component can be powered at low voltage for several hours) to restore insulation resistance.


Keywords: HRY Series Sheathed Electric Heater, HRY Series Sheathed Electric Heater