Example of nitrogen electric heater power calculation, where the calculated power of the nitrogen electric heater is 1380KW.
Basic design conditions for nitrogen electric heater:
Working pressure 0.35~1.50MPa (gauge pressure), design pressure 2.00MPa (gauge pressure); inlet nitrogen temperature of electric heater 35~230℃, outlet nitrogen temperature 200~430℃, outlet design temperature 450℃; normal gas flow rate 12750m³/h (standard condition), maximum gas flow rate 15000m³/h (standard condition).
Nitrogen electric heater power calculation formula: P=E×C×ρ×Q×△T
Where: E—Safety factor, taken as 1.3 (recommended value);
P—Power required for medium temperature rise, W;
C—Specific heat of medium, J/(g·℃);
 