Selection of Explosion-Proof Electric Heaters, Is It Like This? - Yangzhou Darui
Darui Electric recommends for you
Selection of Explosion-Proof Electric Heaters, Is It Like This?
Explosion-proof electric heater is a device that consumes electrical energy to convert into heat energy to heat the material to be heated. Its designed surface power load is low, and multiple protections are adopted to greatly increase the safety and life of the explosion-proof electric heater. And according to requirements, through the circuit design of the explosion-proof electric heater, it can conveniently realize automatic control of parameters such as outlet temperature, flow, pressure, etc., with obvious energy-saving results, and almost 100% of the heat generated by electric energy is transferred to the heating medium.
How to choose a suitable explosion-proof electric heater, first consider the power size of the explosion-proof electric heater. Under the condition of meeting the time parameters, choosing the power is to meet the heat required by the heating medium, ensuring that the explosion-proof electric heater can achieve the heating purpose and operate normally.
Since the thermal efficiency of electric heating is close to 1, it can be considered that the power of the explosion-proof electric heater is the heat output.
1. Considerations for power selection
The calculation and selection of power should consider the following three points:
(1) From the initial state, heat the medium to the set temperature (working temperature) within the specified time;
(2) Under working conditions, the heat output is sufficient to maintain the medium temperature;
(3) There should be a certain safety margin, generally taken as 1.2.
Obviously, choose the larger power from (1) and (2), and multiply by the safety margin to get the selected power.
2. Calculation of power required for heating from initial state
(1) Static fluid heating
(2) Flowing fluid heating
(3) Air duct type explosion-proof electric heater for atmospheric air heating
In the above three formulas
P_calc —— Required power of explosion-proof electric heater (KW);
Q_diss —— Heat dissipation of the container at the set temperature (KW);
Where:
C1 — Specific heat of the heated medium (Kcal/(kg?℃)
C2 — Specific heat of the container (system) (Kcal/(kg?℃)
M1 — Mass of the heated medium (Kg);
M2 — Mass of the container (system) (Kg);
ΔT — Difference between set temperature and initial temperature (℃);
t — Time required to heat the medium from initial temperature to set temperature (h);
F — Flow rate of the heating medium (generally take the maximum flow) (m/min);
S — Heat dissipation area (m2);
q_loss — Heat loss per unit area of (insulation) material at set temperature (Kwh/m)
3. Calculation of power required to maintain medium temperature
Where:
P_main — Power required to maintain medium temperature of explosion-proof electric heater (KW)
M1_inc — Increased medium mass per hour (Kg/h)
Explosion-proof electric heater in operation, the low-temperature fluid medium enters its inlet through the pipeline under pressure, flows along the specific heat exchange channel inside the electric heating container, following the path designed by fluid thermodynamics principles, takes away the high-temperature heat energy generated by the electric heating element during operation, causing the temperature of the heated medium to rise, and the outlet of the explosion-proof electric heater obtains the high-temperature medium required by the process.
The internal high-voltage system of the explosion-proof electric heater can provide alarm signals such as operation, high temperature, fault, shutdown to the DCS system, and can also accept automatic, shutdown and other operation commands issued by DCS. Moreover, a reliable and safe monitoring device is added to the explosion-proof electric heater system, but the price reference of the explosion-proof electric heater is relatively higher.

Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.