Maintenance Points for SDX-25 Duct-Type Industrial Electric Heater

Published: 2026-10-14

产品价格:0.00

Views: 2922

Category: Electric Heating I

Product Description

Troubleshooting of Heating Tube Vibration and Junction Box Over-Temperature

After long-term operation of a duct-type industrial electric heater, maintenance personnel may encounter vibration of the heating tubes caused by airflow pulsation and frequent operation of the over-temperature control device inside the junction box. Such problems are mostly related to loose support structures or dust accumulation in the duct. It is recommended to check the tightening status of the steel plate supports every quarter, clean the attachments on the surface of the heating tubes, and verify whether the set value of the over-temperature protector in the junction box matches the current working conditions. If vibration persists, temperature-resistant damping pads can be added at the support points.

Daily Inspection Items for Explosion-Proof Locations

For equipment used in explosion-proof locations such as chemical, petroleum, and natural gas facilities, it is necessary to focus on confirming whether the flameproof surfaces are corroded and whether the sealing rings of the cable entry devices are aged. During inspection, a torque wrench should be used to recheck the bolt tightening torque to avoid damaging explosion-proof performance due to looseness. It is strictly prohibited to open the junction box while it is energized. If damage to the flameproof surface is found, professional personnel should be contacted to evaluate and repair it; do not grind or handle it by yourself.

Calibration Method for Working Temperature Control

Temperature control deviation directly affects heating effect and safety. It is recommended to calibrate the temperature control instrument once every six months, comparing the deviation between the actual duct outlet temperature and the displayed value. If the deviation exceeds the allowable range, check whether the thermocouple installation position has shifted and whether the compensation wire connection is reliable. For the three specifications of low temperature, medium temperature, and high temperature, the calibration cycle can be appropriately adjusted according to usage frequency, but it should not exceed one year.

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us